• DocumentCode
    2765918
  • Title

    The design of peripheral circuits of inductive coupling type electrodeless discharge lamp

  • Author

    Yokozeki, I. ; Shimokawa, T. ; Kato, Y. ; Ohkita, M. ; Takahashi, N. ; Nakaoka, M.

  • Author_Institution
    Harison Toshiba Lighting Corp., Kanagawa, Japan
  • Volume
    2
  • fYear
    2003
  • fDate
    17-20 Nov. 2003
  • Firstpage
    1137
  • Abstract
    Recently, the ultraviolet disinfection is spreading in place of the chlorine sterilization that affects the ecosystem of the downstream in the river. In this paper, the new lighting system of electrodeless discharge lamp for ultraviolet disinfection is proposed, which realized high safety and long life. By developing the method for stably supplying the necessary electric power to the lamp in the case of the low coil voltage, it became possible to extend the life of the discharge lamp, and to improve reliability of the equipment. By experiments, the practicability of the proposed system could be confirmed.
  • Keywords
    electrodeless lamps; lighting; ultraviolet sources; chlorine sterilization; ecosystem; electric power supply; electrodeless discharge lamp; exciting coil; inductive coupling; lighting system; peripheral circuit design; ultraviolet disinfection; Coaxial cables; Coils; Coupling circuits; Ecosystems; Frequency; Lamps; Optical coupling; Power supplies; Power system reliability; Rivers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Drive Systems, 2003. PEDS 2003. The Fifth International Conference on
  • Print_ISBN
    0-7803-7885-7
  • Type

    conf

  • DOI
    10.1109/PEDS.2003.1283133
  • Filename
    1283133