• DocumentCode
    2769795
  • Title

    Novel type of microcantielver biosesor resonating at the interface between liquid and air

  • Author

    Park, J. ; Nishida, S. ; Kawakatsu, H. ; Fujita, H.

  • Author_Institution
    Inst. of Ind. Sci., Univ. of Tokyo, Tokyo, Japan
  • fYear
    2011
  • fDate
    23-27 Jan. 2011
  • Firstpage
    948
  • Lastpage
    951
  • Abstract
    We developed a new type of a microcantilever biosensor resonating at the interface between air and liquid. The cantilever sensor has advantages in high signal-to-noise ratio (SNR) and high quality factor (Q-factor) for detecting bio-reactions because liquid damping acts on only one-side, and because there is no obstacle between detection, excitation lasers and the cantilever. (Fig. 1 (c)) Using the cantilever integrated with a microchannel and phase locked loop detection, we measured adsorption reaction kinetics of carboxylated microspheres in real time for three different concentrations.
  • Keywords
    Q-factor; adsorption; bioMEMS; biosensors; cantilevers; damping; microchannel flow; microfabrication; microsensors; phase locked loops; reaction kinetics; Q-factor; adsorption reaction kinetics; bio-reactions; carboxylated microspheres; excitation lasers; liquid damping; microcantielver biosesor; microchannel; phase locked loop detection; quality factor; resonation; signal-to-noise ratio; Biosensors; Frequency measurement; Measurement by laser beam; Microchannel; Pumps; Resonant frequency; Silicon;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Micro Electro Mechanical Systems (MEMS), 2011 IEEE 24th International Conference on
  • Conference_Location
    Cancun
  • ISSN
    1084-6999
  • Print_ISBN
    978-1-4244-9632-7
  • Type

    conf

  • DOI
    10.1109/MEMSYS.2011.5734583
  • Filename
    5734583