• DocumentCode
    2773098
  • Title

    Micro gap measurement by vibration mode for needle-type dispenser

  • Author

    Hirose, Kazuki ; Irie, Yuuka ; Hirata, Shinnosuke ; Aoyama, Hisayuki

  • Author_Institution
    Dept. of Mech. Eng. & Intell. Syst., Univ. of Electro-Commun., Chofu, Japan
  • fYear
    2011
  • fDate
    7-10 Aug. 2011
  • Firstpage
    555
  • Lastpage
    560
  • Abstract
    A needle-type dispenser, consists of a thin needle and a glass capillary, has been developed for micro-droplet application from high viscosity liquids. A gap, which is a distance between the needle tip and the target surface, is formed in micro-droplet. If the gap is fluctuated, volumes of applied micro droplets are unstable. Therefore, a contact-detection method of the needle-tip droplet and the target surface is proposed. The needle is vibrated by the piezoelectric element through the leaf spring in the proposed method. Contact of the needle-tip droplet and the target surface can be detected from needle-vibration characteristics. In this paper, control of the gap and droplet volume using needle-vibration characteristics is reported.
  • Keywords
    displacement measurement; drops; mechatronics; needles; vibration measurement; glass capillary; micro gap measurement; needle-tip droplet; needle-type dispenser; piezoelectric element; thin needle; vibration mode; Frequency measurement; Frequency response; Needles; Resistance; Resonant frequency; Springs; Vibrations; micro gap control; needle vibration; needle-type dispenser; piezo actuator; resonance frequency;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mechatronics and Automation (ICMA), 2011 International Conference on
  • Conference_Location
    Beijing
  • ISSN
    2152-7431
  • Print_ISBN
    978-1-4244-8113-2
  • Type

    conf

  • DOI
    10.1109/ICMA.2011.5985721
  • Filename
    5985721