DocumentCode
2773235
Title
Experimental study of estimating SAR values for mobile phone applications
Author
Chen, I-Fong ; Peng, Chia-Mei ; Hung, Ching-Chih
Author_Institution
Inst. of C.C.E, Jin-Wen Univ. of Sci. & Technol., Taipei
fYear
2008
fDate
5-11 July 2008
Firstpage
1
Lastpage
4
Abstract
A novel method is presented that accurately and quickly estimates the peak 1-g or 10-g averaged specific absorption rate (SAR) in a human phantom when exposed to a mobile handset, based on experimental studies. The accuracy of the algorithm has been demonstrated across different systems (CDMA, GSM, DCS, PCS and WCDMA) and for both 1-g and 10-g averaged SAR using a sample of 96 SAR measurements from 4 type mobile handsets. For the sample size studied, the root-mean-squared errors of the algorithm are 17% and 15% for 1-g and 10-g averaged SAR, respectively.
Keywords
mean square error methods; mobile communication; SAR values; mobile phone; root-mean-squared errors; specific absorption rate; Distributed control; GSM; Humans; Imaging phantoms; Mobile handsets; Multiaccess communication; Position measurement; Specific absorption rate; Telephone sets; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Antennas and Propagation Society International Symposium, 2008. AP-S 2008. IEEE
Conference_Location
San Diego, CA
Print_ISBN
978-1-4244-2041-4
Electronic_ISBN
978-1-4244-2042-1
Type
conf
DOI
10.1109/APS.2008.4619665
Filename
4619665