DocumentCode
27739
Title
Open-Switch Fault Tolerance Control for a Three-Level NPC/T-Type Rectifier in Wind Turbine Systems
Author
June-Seok Lee ; Kyo-Beum Lee
Author_Institution
Dept. of Electr. & Comput. Eng., Ajou Univ., Suwon, South Korea
Volume
62
Issue
2
fYear
2015
fDate
Feb. 2015
Firstpage
1012
Lastpage
1021
Abstract
Three-level topologies are widely used in back-to-back converters of wind turbine generation (WTG) systems. In comparison with a conventional two-level topology, three-level topologies have more advantages, particularly for the high power. Neutral-point clamped (NPC) and T-type are typical three-level topologies. An open-switch fault of a three-level rectifier that is connected to a permanent-magnet synchronous generator (PMSG) leads to the current distortion and torque vibration in WTG systems. Furthermore, WTG systems can break down in the worst case. Therefore, a tolerance control for open-switch faults is required to improve the reliability of WTG systems. WTG systems by applying the tolerance control can be stopped safely and prevent additional problems. Depending on the situation, it can keep the operation of WTG systems under open-switch fault. The effects of outer open-switch faults of three-level rectifiers are analyzed by considering PMSG specifications in this paper. Moreover, a tolerance control for outer open-switch faults of the NPC and T-type three-level rectifiers are proposed with existing tolerance controls for inner open-switch faults. The proposed tolerance control is to inject the exact $d$-axis current value to eliminate current distortion. The simulation and experiment are conducted to prove the feasibility of the proposed tolerance control and to identify its performance.
Keywords
permanent magnet generators; power generation control; power generation reliability; rectifiers; synchronous generators; wind turbines; PMSG specifications; WTG systems reliability; back-to-back converters; current distortion; neutral-point clamped; open-switch fault tolerance control; permanent-magnet synchronous generator; three-level NPC T-type rectifier; three-level rectifier; three-level topologies; torque vibration; two-level topology; wind turbine generation; wind turbine systems; Circuit faults; Inverters; Modulation; Rectifiers; Switches; Topology; Vectors; Neutral-point-clamped (NPC) rectifier; T-type rectifier; open-switch fault; three-level rectifier; tolerance control;
fLanguage
English
Journal_Title
Industrial Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0278-0046
Type
jour
DOI
10.1109/TIE.2014.2347912
Filename
6878436
Link To Document