DocumentCode :
2774925
Title :
Effects of shielding enclosures on the breakdown failure rate of electronic equipment
Author :
Herlemann, Helge ; Fisahn, Sven ; Koch, Michael ; Garbe, Heyno
Author_Institution :
Inst. of the Basics of Electr. Eng. & Meas. Sci., Leibniz Univ. Hannover, Hannover
fYear :
2008
fDate :
8-12 Sept. 2008
Firstpage :
1
Lastpage :
5
Abstract :
As a criterion of quality of a shield regarding its ability to protect electronic equipment against electromagnetic pulses, the breakdown failure rate of an operating test equipment with and without the shield can be compared [1]. In this contribution, the shielding behavior of cubical shields with varying rectangular slots against ultra wideband pulses of double exponential wave form is studied. It is found out, that applying the shield may have the effect, that electronic equipment becomes even more vulnerable to pulses due to resonance effects inside the enclosure. The results of these examinations in time domain are compared to results in frequency domain which can be found in literature [2].
Keywords :
electromagnetic pulse; electronic equipment testing; magnetic shielding; breakdown failure rate; cubical shields; double exponential wave form; electromagnetic pulses; electronic equipment; operating test equipment; rectangular slots; shielding enclosures; ultra wideband pulses; Apertures; Circuit testing; EMP radiation effects; Electric breakdown; Electromagnetic measurements; Electronic equipment; Frequency measurement; Protection; Pulse measurements; Resonance; UWB-pulses; rectangular enclosure with rectangular aperture; shielding effectiveness;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility - EMC Europe, 2008 International Symposium on
Conference_Location :
Hamburg
Print_ISBN :
978-1-4244-2737-6
Electronic_ISBN :
978-1-4244-2737-6
Type :
conf
DOI :
10.1109/EMCEUROPE.2008.4786905
Filename :
4786905
Link To Document :
بازگشت