DocumentCode
279278
Title
Traceable dielectric measurements by resonance methods in the frequency range 1-30 MHz
Author
Hill, G.J.
Author_Institution
ERA Technol. Ltd., Leatherhead, UK
fYear
1992
fDate
7-10 Sep 1992
Firstpage
108
Lastpage
110
Abstract
It is shown that traceable Q measurements on a stable inductor can provide the basis for dielectric measurements in the frequency range 1-30 MHz. It is also possible to adapt computer controlled four terminal impedance measuring techniques by coupling them with a resonance adaptor and suitable test fixture, so that dielectric measurements may be made to ±2% in permittivity and ±5μ rad in dielectric loss
Keywords
Q-factor measurement; computerised instrumentation; dielectric loss measurement; inductors; permittivity measurement; 1 to 30 MHz; computer controlled; dielectric loss; dielectric measurements; four terminal impedance measuring techniques; permittivity; resonance adaptor; resonance methods; stable inductor; test fixture; traceable Q measurements;
fLanguage
English
Publisher
iet
Conference_Titel
Dielectric Materials, Measurements and Applications, 1992., Sixth International Conference on
Conference_Location
Manchester
Print_ISBN
0-85296-551-6
Type
conf
Filename
186893
Link To Document