• DocumentCode
    279288
  • Title

    Diagnostic techniques for the field evaluation of polymer concrete insulators

  • Author

    Fierro-Chavez, J.L. ; Duguid, T.P.

  • Author_Institution
    Inst. de Investigaciones Electr., Cuernavaca, Mexico
  • fYear
    1992
  • fDate
    7-10 Sep 1992
  • Firstpage
    146
  • Lastpage
    149
  • Abstract
    Several diagnostic techniques were employed in order to develop a methodology to evaluate the field performance of polymer concrete pin type insulators. These will be installed in the UK overhead distribution network under various weathering and pollution conditions. The techniques used include measurements such as surface roughness, water contact angle, surface resistance under clean fog conditions and flashover voltage under artificial pollution conditions. Results of these measurements are given for new and aged insulators. From the results, it is concluded that the evaluation methodology is a valuable tool for diagnosis of the effect of surface changes on the electrical performance of polymer concrete insulators
  • Keywords
    composite insulating materials; concrete; contact angle; environmental testing; filled polymers; flashover; insulation testing; insulators; surface topography measurement; aged insulators; artificial pollution conditions; clean fog conditions; diagnostic techniques; electrical performance; field performance; flashover voltage; overhead distribution network; pin type insulators; polymer concrete insulators; surface resistance; surface roughness; water contact angle;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Dielectric Materials, Measurements and Applications, 1992., Sixth International Conference on
  • Conference_Location
    Manchester
  • Print_ISBN
    0-85296-551-6
  • Type

    conf

  • Filename
    186903