    Modular ESS with second life batteries operating in grid independent mode

  • Author

    Mukherjee, Nandini ; Strickland, Dani

  • Author_Institution
    Dept. of Electr., Electron. & Power Eng., Aston Univ., Birmingham, UK
  • fYear
    2012
  • fDate
    25-28 June 2012
  • Firstpage
    653
  • Lastpage
    660
  • Abstract
    This work is part of a bigger project which aims to research the potential development of commercial opportunities for the re-use of batteries after their use in low carbon vehicles on an electricity grid or microgrid system. There are three main revenue streams (peak load lopping on the distribution Network to allow for network re-enforcement deferral, National Grid primary/ secondary/ high frequency response, customer energy management optimization). These incomes streams are dependent on the grid system being present. However, there is additional opportunity to be gained from also using these batteries to provide UPS backup when the grid is no longer present. Most UPS or ESS on the market use new batteries in conjunction with a two level converter interface. This produces a reliable backup solution in the case of loss of mains power, but may be expensive to implement. This paper introduces a modular multilevel cascade converter (MMCC) based ESS using second-life batteries for use on a grid independent industrial plant without any additional onsite generator as a potentially cheaper alternative. The number of modules has been designed for a given reliability target and these modules could be used to minimize/eliminate the output filter. An appropriate strategy to provide voltage and frequency control in a grid independent system is described and simulated under different disturbance conditions such as load switching, fault conditions or a large motor starting. A comparison of the results from the modular topology against a traditional two level converter is provided to prove similar performance criteria. The proposed ESS and control strategy is an acceptable way of providing backup power in the event of loss of grid. Additional financial benefit to the customer may be obtained by using a second life battery in this way.
  • Keywords
    battery storage plants; distributed power generation; distribution networks; energy storage; frequency control; industrial plants; power generation reliability; power grids; uninterruptible power supplies; voltage control; MMCC; UPS backup; customer energy management optimization; distribution network; disturbance conditions; energy storage system; fault conditions; frequency control; grid independent industrial plant; grid independent mode; grid independent system; high frequency response; load switching; low carbon vehicles; microgrid system; modular ESS; modular multilevel cascade converter; motor starting; network reenforcement deferral; onsite generator; output filter; reliability target; second life batteries; second life battery; two level converter interface; voltage control; Batteries; Equations; Frequency control; Frequency measurement; Reliability; Topology; Voltage control; Energy Storage System (ESS); Grid independent Operation; Second-life batteries; Voltage and Frequency Control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics for Distributed Generation Systems (PEDG), 2012 3rd IEEE International Symposium on
  • Conference_Location
    Aalborg
  • Print_ISBN
    978-1-4673-2021-4
  • Electronic_ISBN
    978-1-4673-2022-1
  • Type

    conf

  • DOI
    10.1109/PEDG.2012.6254072
  • Filename
    6254072