DocumentCode
2794168
Title
The power handling capacity of slab lines
Author
Badoyannis, G.M.
Author_Institution
Sperry Gyroscope Company, Div. of Sperry Rand Corporation, Great Neck, New York, USA
Volume
2
fYear
1958
fDate
21398
Firstpage
35
Lastpage
38
Abstract
Slab lines consisting of a circular cylindrical inner conductor centrally located between two parallel conducting plates have recently been employed in the development of high-power microwave components. This paper presents an evaluation of the power handling capacity of such lines. The method employed leads to highly accurate results. A power capacity expression is derived in terms of the shape ratio and the characteristic impedance of the line. The variation of this power is plotted as a function of the characteristic impedance for a given outer conductor plate spacing. Finally, the power capacity of this line is compared to that of a coaxial transmission line.
Keywords
Coaxial components; Conductors; Dielectric breakdown; Geometry; Gyroscopes; Impedance; Neck; Power transmission lines; Shape; Slabs;
fLanguage
English
Publisher
ieee
Conference_Titel
WESCON/58 Conference Record
Type
conf
DOI
10.1109/WESCON.1958.1150205