A study on constant slope method for rapid thermal endurance tests of dielectrics
Author
Yingsuo, Zhang ; Yi, Bai
Author_Institution
Xi´´an Res. Inst. of Insulating Mater., China
fYear
1991
fDate
8-12 Jul 1991
Firstpage
1225
Abstract
It has been found that the accuracy of the constant slope (CS) method was ±16.6°C as compared with conventional aging (CA) (its standard deviation of error Δt , S =8.3°C). A scientific approach to the study of the CS method is presented here. It is noted that this method possesses a certain investigation value, and may be able to help one understand the change law of activation energy in CA, as well as present the complex relation between various rapid methods in order to explore the possibility of developing a higher-accuracy and really practical rapid method
Keywords
insulating coatings; insulation testing; life testing; varnish; activation energy; change law; constant slope method; conventional aging; rapid thermal endurance tests; Aging; Costs; Dielectric materials; Dielectrics and electrical insulation; IEC standards; Kinetic theory; Life testing; Materials testing; Pattern analysis; Temperature;