• DocumentCode
    2797149
  • Title

    A study on constant slope method for rapid thermal endurance tests of dielectrics

  • Author

    Yingsuo, Zhang ; Yi, Bai

  • Author_Institution
    Xi´´an Res. Inst. of Insulating Mater., China
  • fYear
    1991
  • fDate
    8-12 Jul 1991
  • Firstpage
    1225
  • Abstract
    It has been found that the accuracy of the constant slope (CS) method was ±16.6°C as compared with conventional aging (CA) (its standard deviation of error Δt, S=8.3°C). A scientific approach to the study of the CS method is presented here. It is noted that this method possesses a certain investigation value, and may be able to help one understand the change law of activation energy in CA, as well as present the complex relation between various rapid methods in order to explore the possibility of developing a higher-accuracy and really practical rapid method
  • Keywords
    insulating coatings; insulation testing; life testing; varnish; activation energy; change law; constant slope method; conventional aging; rapid thermal endurance tests; Aging; Costs; Dielectric materials; Dielectrics and electrical insulation; IEC standards; Kinetic theory; Life testing; Materials testing; Pattern analysis; Temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Properties and Applications of Dielectric Materials, 1991., Proceedings of the 3rd International Conference on
  • Conference_Location
    Tokyo
  • Print_ISBN
    0-87942-568-7
  • Type

    conf

  • DOI
    10.1109/ICPADM.1991.172300
  • Filename
    172300