• DocumentCode
    2797729
  • Title

    Valve regulated batteries-losses of water and hydrogen through the valves and the battery containers at elevated temperatures

  • Author

    Karlsson, Gunder

  • Author_Institution
    Catella Generics AB, Kista, Sweden
  • fYear
    1991
  • fDate
    5-8 Nov 1991
  • Firstpage
    26
  • Lastpage
    31
  • Abstract
    During accelerated testing of valve-regulated (VR) batteries there have been uncertainties about the failure modes and the accelerating factors involved. An experimental study has been performed with the batteries in an enclosed environment where the gases given off by the battery at elevated temperatures have been measured. The diffusive leakage of water and hydrogen as well as the vented gases have been measured. The results are discussed in terms of rate of dry out and corrosion. The influence of different VR-technologies is also discussed
  • Keywords
    life testing; losses; secondary cells; H2 losses; H2O losses; accelerated testing; accelerating factors; corrosion; diffusive leakage; dry out; elevated temperatures; failure modes; valve-regulated batteries; vented gases; Battery charge measurement; Containers; Corrosion; Gases; Hydrogen; Life estimation; Temperature measurement; Testing; Valves; Virtual reality;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Telecommunications Energy Conference, 1991. INTELEC '91., 13th International
  • Conference_Location
    Kyoto
  • Print_ISBN
    0-87942-670-5
  • Type

    conf

  • DOI
    10.1109/INTLEC.1991.172368
  • Filename
    172368