  • Title

    LCOE reduction for megawatts PV system using efficient 500 kW transformerless inverter

  • Author

    Chen, Jeng-Yue ; Hung, Chia-Han ; Gilmore, Jack ; Roesch, Jeff ; Zhu, Wei

  • fYear
    2010
  • fDate
    12-16 Sept. 2010
  • Firstpage
    392
  • Lastpage
    397
  • Abstract
    This paper presents the cost advantages that a high-performance, 500 kW, transformerless PV inverter can have for the megawatts solar farm system. Higher efficiency, smaller size, and lower installation costs impact balance-of -system (BoS) costs and reducing the levelized cost of energy (LCOE) compared with traditional, transformer-based PV inverters. These cost advantages should be considered as system integrators and end-users. This paper focuses on the effect of a higher efficient PV inverter on BoS cost and LCOE, analyzing real PV grid-connected, transformerless inverter applications as well as unipolar and bipolar PV array configurations. Some key parameters and specifications for the PV inverters are introduced. The simulation of LCOE was done by using the software, Solar Advisory Model (SAM) and using PVSYST software to simulate the system performance and loss with PV module, inverter, and weather data. The simulation result is presented based on a 10 MW PV system in Atlanta, U.S.
  • Keywords
    invertors; photovoltaic power systems; power generation economics; levelized cost of energy reduction; megawatts solar farm system; photovoltaic system; power 10 MW; power 500 kW; transformerless inverter; Arrays; Cooling; Inverters; Mathematical model; Meteorology; Power harmonic filters; Power system stability; BoS; LCOE; Transformerless Inverter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Energy Conversion Congress and Exposition (ECCE), 2010 IEEE
  • Conference_Location
    Atlanta, GA
  • Print_ISBN
    978-1-4244-5286-6
  • Electronic_ISBN
    978-1-4244-5287-3
  • Type

    conf

  • DOI
    10.1109/ECCE.2010.5618002
  • Filename
    5618002