    Analysis to heat loss of steam pipeline network in economic development zone

  • Author

    Gang, Shen ; Shijun, You ; Wenzhong, Wu

  • Author_Institution
    Sch. of Environ. Sci. & Technol., Tianjin Univ., Tianjin, China
  • fYear
    2011
  • fDate
    15-17 July 2011
  • Firstpage
    2911
  • Lastpage
    2914
  • Abstract
    Energy conservation and rational usage of energy is China´s basic national policy. The present steam consumption and heat loss of its pipeline network in Tianjin airport economic development zone is recorded, then zonal steam distribution efficiency is calculated to be 37.56 % by the steam consumption data, and zonal heat loss is in inverse proportion to steam distribution efficiency with factor of 8.312 × 104 kW, that is, in direct proportion to steam produce, steam enthalpy difference, inverse proportion to steam consumption with factor of 83.12 kW by the steam distribution efficiency, offering reasons to optimize steam pipeline network operation, and cover steam requirement with minimal energy consumption.
  • Keywords
    energy conservation; energy consumption; enthalpy; heat losses; pipelines; steam power stations; China basic national policy; Tianjin airport economic development zone; efficiency 37.56 percent; energy conservation; heat loss analysis; minimal energy consumption; power 83.12 kW; steam consumption; steam enthalpy difference; steam pipeline network; zonal heat loss; zonal steam distribution efficiency; Buildings; Cogeneration; Economics; Equations; Pipelines; economic development zone; energy distribution efficiency; heat loss; steam pipeline network;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mechanic Automation and Control Engineering (MACE), 2011 Second International Conference on
  • Conference_Location
    Hohhot
  • Print_ISBN
    978-1-4244-9436-1
  • Type

    conf

  • DOI
    10.1109/MACE.2011.5987596
  • Filename
    5987596