Title :
Landfill leachate treatment by electrocoagulation
Author_Institution :
Coll. of Civil Eng. & Archit., Liaoning Univ. of Technol., Jinzhou, China
Abstract :
Electrocoagulation was used to treat landfill leachate effluent from biochemical process. The influence factors including polar plate material, pH, polar plate space, current intensity and electro coagulation time were investigated. The optimum condition was using iron as polar plate, polar plate space 20mm, pH 7-9, current intensity 3A, electrocoagulation time 30min. At this condition, CODcr removal rate was 73.9%, ammonia removal rate 64.3% and BOD5 removal rate was 49.2%.
Keywords :
coagulation; effluents; pH; waste management; BOD5 removal; ammonia removal; biochemical process; electrocoagulation; landfill leachate effluent treatment; landfill leachate treatment; pH; polar plate material; polar plate space; Aluminum; Effluents; Hazardous materials; Iron; Waste management; Wastewater; eleotrocoagulation; iron polar plate; landfill leachate;
Conference_Titel :
Mechanic Automation and Control Engineering (MACE), 2011 Second International Conference on
Conference_Location :
Hohhot
Print_ISBN :
978-1-4244-9436-1
DOI :
10.1109/MACE.2011.5987671