Title
Sizing of small voids less than focused beam diameter with C-scan acoustic microscope
Author
NISHIMURA, Naoya ; Kawashima, Koichiro ; Ikeda, Yasushi
Author_Institution
Dept. of Mech. Eng., Nagoya Inst. of Technol., Japan
Volume
2
fYear
1998
fDate
1998
Firstpage
1325
Abstract
The small objects which are far less than the focused beam diameter were imaged with a C-scan acoustic microscope, and the acoustic image sizes were compared with the actual sizes. The sizes of flat strips of width over 0.01 mm and steel wires of diameter over 0.02 mm were estimated within 30% error by using the reflection ratio, which is the ratio of the intensity of reflection signal from an object to that from a reference plane. The validity of this method is also shown for small spherical voids within ceramics
Keywords
acoustic focusing; acoustic microscopy; ultrasonic materials testing; voids (solid); C-scan acoustic microscope; acoustic image; ceramic; flat strip; focused ultrasonic beam; reflection ratio; steel wire; void sizing; Acoustic beams; Acoustic reflection; Ceramics; Focusing; Microscopy; Optical reflection; Steel; Strips; Ultrasonic transducers; Wires;