DocumentCode
2806359
Title
New core loss measurement method for high frequency magnetic materials
Author
Mu, Mingkai ; Li, Qiang ; Gilham, David ; Lee, Fred C. ; Ngo, Khai D T
Author_Institution
Center for Power Electron. Syst., Virginia Polytech. & State Univ., Blacksburg, VA, USA
fYear
2010
fDate
12-16 Sept. 2010
Firstpage
4384
Lastpage
4389
Abstract
Magnetic core loss is an emerging concern for integrated POL converters. As switching frequency increases, core loss is comparable to or even higher than winding loss. Accurate measurement of core loss is important for magnetic design and converter loss estimation. And exploring new high frequency magnetic materials need a reliable method to evaluate their losses. However, conventional method is limited to low frequency due to sensitivity to phase discrepancy. In this paper, a new method is proposed for high frequency (lMHz~50MHz) core loss measurement. The new method reduces the phase induced error from over 100% to <;5%. So with the proposed methods, the core loss can be accurately measured.
Keywords
frequency measurement; load (electric); loss measurement; magnetic cores; magnetic materials; switching convertors; converter loss estimation; high frequency core loss measurement; high frequency magnetic material; integrated POL converter; magnetic core loss; point-of-load converter; switching frequency; Capacitors; Core loss; Current measurement; Frequency measurement; Loss measurement; Sensors; Windings; core loss measurement; ferrite; high frequency; integrated POL; magnetic loss;
fLanguage
English
Publisher
ieee
Conference_Titel
Energy Conversion Congress and Exposition (ECCE), 2010 IEEE
Conference_Location
Atlanta, GA
Print_ISBN
978-1-4244-5286-6
Electronic_ISBN
978-1-4244-5287-3
Type
conf
DOI
10.1109/ECCE.2010.5618454
Filename
5618454
Link To Document