Title :
Partial discharge patterns of magnet wire samples under voltage stresses
Author :
Grzybowski, S. ; Mani, A. ; Taylor, C.D.
Author_Institution :
Mississippi State Univ., MS, USA
Abstract :
In many high voltage systems, partial discharges are an indication of insulation condition. The partial discharge test is a nondestructive method of identifying possible premature insulation breakdown. Magnet wires are used in various electrical equipments like injection coils, solenoids and small transformers. The aging process of the wire insulation was achieved through the application of high voltages, high temperature and high frequency. The tests were conducted for AWG 30 and AWG 31 twisted magnet wire samples. A high level of stress is present within several turns of coil windings. This paper is focused on the study of partial discharge patterns for magnet wire insulation. The partial discharge inception voltages (PDIV) are measured for different twisted wire samples. An evaluation of the parameters charge intensity, pulse count, and pulse phase position are presented in 2- and 3-dimensional plots.
Keywords :
ageing; electric breakdown; high-voltage techniques; insulated wires; nondestructive testing; partial discharge measurement; twisted pair cables; voltage measurement; AWG 30 twisted magnet wire; AWG 31 twisted magnet wire; aging process; charge intensity; coil winding; electrical equipment; high voltage system; injection coil; nondestructive method; partial discharge inception voltage measurement; partial discharge test; premature insulation breakdown; pulse phase position; solenoid; transformer; voltage stress; wire insulation; Cable insulation; Coils; Electric breakdown; Insulation testing; Nondestructive testing; Partial discharges; Power transformer insulation; Stress; Voltage; Wire;
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 2005. CEIDP '05. 2005 Annual Report Conference on
Print_ISBN :
0-7803-9257-4
DOI :
10.1109/CEIDP.2005.1560710