Abstract
This paper presents the testing of EarthCARE extended interaction klystron by lifetest vehicles. The cathodes to be lifetested are the so called Triple alloy cathodes (TA- cathodes), which are standard M-type dispenser cathodes that undergo a coating process to lower the work function. The measured cathode work function at full current is approximately 1.84 eV and exhibiting very small variation amongst the 5 LTV´s. Similarly, the measured knee brightness temperature is very uniform and is around 990 °C at full current.
Keywords
cathodes; klystrons; life testing; work function; 990 degC; EarthCARE extended interaction klystron; M type dispenser cathodes; brightness temperature; cathode lifetesting; coating process; triple alloy cathodes; work function; Brightness temperature; Cathodes; Clouds; Current measurement; Earth; Klystrons; Temperature measurement; Testing; Vehicles; Voltage;