DocumentCode :
2811014
Title :
External Work of Breathing of Demand-Air Underwater Breathing Apparatus
Author :
Grodski, J.
Author_Institution :
Defence and Civil Institute of Environmental Medicine, Downsview, Ontario, Canada
fYear :
1978
fDate :
6-8 Sept. 1978
Firstpage :
115
Lastpage :
121
Abstract :
Underwater breathing apparatus can be effectively evaluated by measuring the external work of breathing. This paper reviews the existing and the proposed standards for demand-air breathing apparatus and recommends improvements to the Bentley-Reimers criterion. An automated method of collecting data on the external work of breathing is also described along with test results of various demand-air breathing apparatus. The test and evaluation data in this paper support the proposed, modified Bentley-Reimers criterion.
Keywords :
Area measurement; Automatic testing; Hoses; Measurement units; Mouth; Pressure measurement; Proposals; Regulators; Surface impedance; Ventilation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
OCEANS '78
Conference_Location :
Washington, DC, USA
Type :
conf
DOI :
10.1109/OCEANS.1978.1151166
Filename :
1151166
Link To Document :
بازگشت