• DocumentCode
    281119
  • Title

    Current practice in the design of closed circuit air cooled machine coolers

  • Author

    Atkin, M.L.

  • fYear
    1992
  • fDate
    33904
  • Firstpage
    42491
  • Lastpage
    42494
  • Abstract
    The basic thermal design methods for air to air heat exchangers for use in electrical machine cooling applications have changed little since the early 1970s. The correlations for heat transfer and pressure drops across and through arrays of plain tubes are well established. It is therefore, in related design areas that specifications and design solutions have developed. The author looks at the major areas of design and range of options open to designers including thermal design, equipment layout, noise, and vibration
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Thermal Aspects of Machines, IEE Colloquium on
  • Conference_Location
    London
  • Type

    conf

  • Filename
    193664