DocumentCode
281119
Title
Current practice in the design of closed circuit air cooled machine coolers
Author
Atkin, M.L.
fYear
1992
fDate
33904
Firstpage
42491
Lastpage
42494
Abstract
The basic thermal design methods for air to air heat exchangers for use in electrical machine cooling applications have changed little since the early 1970s. The correlations for heat transfer and pressure drops across and through arrays of plain tubes are well established. It is therefore, in related design areas that specifications and design solutions have developed. The author looks at the major areas of design and range of options open to designers including thermal design, equipment layout, noise, and vibration
fLanguage
English
Publisher
iet
Conference_Titel
Thermal Aspects of Machines, IEE Colloquium on
Conference_Location
London
Type
conf
Filename
193664