DocumentCode :
2813072
Title :
A multi-step phase calibration procedure for closely spaced multi-tone signals
Author :
Mirra, M. ; Marchetti, M. ; Tessitore, F. ; Spirito, M. ; de Vreede, L.C.N. ; Betts, L.
Author_Institution :
Delft Univ. of Technol., Delft, Netherlands
fYear :
2010
fDate :
28-28 May 2010
Firstpage :
1
Lastpage :
5
Abstract :
In this work we present a novel phase calibration procedure suitable for the waveform reconstruction of closely spaced multi-tone signals. The proposed multi-step calibration approach is based on the phase alignment of the calibration error terms measured with different frequency grids generated by the harmonic phase reference. The method achieves a reduction in the needed multiplication order of the phase reference to cover the intended measurement frequency range. The calibration procedure is implemented on an Agilent PNA-X platform, which uses external hardware extensions, e.g. low frequency bridges, for the accurate measurement of the baseband frequency components.
Keywords :
calibration; network analysers; signal reconstruction; Agilent PNA-X platform; calibration error; closely spaced multitone signals; frequency grid generation; harmonic phase reference; multistep phase calibration procedure; nonlinear vector network analyzers; phase alignment; waveform reconstruction; Broadband amplifiers; Calibration; Driver circuits; High power amplifiers; Microwave circuits; Power amplifiers; Power measurement; Radio frequency; Radiofrequency amplifiers; Signal processing; NVNA; multi-tone; phase calibration; waveform reconstruction;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Measurements Conference (ARFTG), 2010 75th ARFTG
Conference_Location :
Anaheim, CA
Print_ISBN :
978-1-4244-6364-0
Type :
conf
DOI :
10.1109/ARFTG.2010.5496320
Filename :
5496320