• DocumentCode
    2813886
  • Title

    Influence of droplet diameter on vortex flow meter in steam flow measurement

  • Author

    Wang, Chao ; Liu, Qin

  • Author_Institution
    Tianjin Key Lab. of Process Meas. & Control, Tianjin Univ., Tianjin, China
  • fYear
    2011
  • fDate
    15-17 July 2011
  • Firstpage
    4994
  • Lastpage
    4997
  • Abstract
    As an important secondary energy, steam is widely used in engineering for its role of heat transfer and mechanical transmission. But steam is a complex medium, its state easily changes as the working condition changes, thus causes measurement error. Based on the present situation, a theoretical analysis has been made on vortex flow meter, which proved that the error was related to steam dryness. Numerical simulations were made to verity that measuring accuracy was related to the droplet diameter condensed out from the steam.
  • Keywords
    drops; error analysis; flow measurement; flow simulation; flowmeters; heat transfer; steam; two-phase flow; vortices; complex medium; droplet diameter; heat transfer; measurement error; mechanical transmission; numerical simulations; secondary energy; steam dryness; steam flow measurement; vortex flow meter; working condition; Automation; Computational fluid dynamics; Energy measurement; Fluid flow measurement; Numerical simulation; Time frequency analysis; flow measurement; numerical simulation; steam; vortex flow meter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mechanic Automation and Control Engineering (MACE), 2011 Second International Conference on
  • Conference_Location
    Hohhot
  • Print_ISBN
    978-1-4244-9436-1
  • Type

    conf

  • DOI
    10.1109/MACE.2011.5988137
  • Filename
    5988137