Influence of droplet diameter on vortex flow meter in steam flow measurement
Author
Wang, Chao ; Liu, Qin
Author_Institution
Tianjin Key Lab. of Process Meas. & Control, Tianjin Univ., Tianjin, China
fYear
2011
fDate
15-17 July 2011
Firstpage
4994
Lastpage
4997
Abstract
As an important secondary energy, steam is widely used in engineering for its role of heat transfer and mechanical transmission. But steam is a complex medium, its state easily changes as the working condition changes, thus causes measurement error. Based on the present situation, a theoretical analysis has been made on vortex flow meter, which proved that the error was related to steam dryness. Numerical simulations were made to verity that measuring accuracy was related to the droplet diameter condensed out from the steam.
Keywords
drops; error analysis; flow measurement; flow simulation; flowmeters; heat transfer; steam; two-phase flow; vortices; complex medium; droplet diameter; heat transfer; measurement error; mechanical transmission; numerical simulations; secondary energy; steam dryness; steam flow measurement; vortex flow meter; working condition; Automation; Computational fluid dynamics; Energy measurement; Fluid flow measurement; Numerical simulation; Time frequency analysis; flow measurement; numerical simulation; steam; vortex flow meter;
fLanguage
English