DocumentCode :
2814515
Title :
Doppler broadening of energy spectra in Compton cameras
Author :
Ordonez, Caesar E. ; Bolozdynya, Alexander ; Chang, Wei
Author_Institution :
Dept. of Med. Phys., St. Lukes Med. Center, Chicago, IL, USA
Volume :
2
fYear :
1997
fDate :
9-15 Nov 1997
Firstpage :
1361
Abstract :
Compton cameras utilize the Compton effect to achieve directional localization of gamma rays. The accuracy of the localization depends, in part, on the uncertainties in the measurement of energies. These uncertainties have conventionally been assumed to be due to the effects of finite detector energy resolution alone. There is another source of energy uncertainty that none of the Compton cameras proposed or built thus far accounts for the Doppler broadening of energy spectra that arises from the Compton interaction between gamma rays and moving electrons bound to atoms. The authors have used Monte Carlo simulations and direct calculations to demonstrate that the energy uncertainties due to Doppler broadening are non-negligible. For low-energy gamma rays, these uncertainties are generally more significant than those due to the finite energy resolutions of semiconductor detectors (for example, germanium and silicon). Expressions for estimating the angular uncertainties in Compton cameras due to energy resolution and Doppler broadening are derived. The authors conclude that the accuracy of the calculation of the scatter angle can be improved if the electron pre-collision momentum is known. However, even without such knowledge. Compton cameras still have the potential to achieve spatial resolutions that are comparable to those of mechanically collimated systems
Keywords :
Compton effect; Doppler broadening; Monte Carlo methods; biomedical equipment; cameras; image resolution; radioisotope imaging; Compton cameras; Ge; Monte Carlo simulations; Si; energy spectra Doppler broadening; finite detector energy resolution; localization accuracy; low-energy gamma rays; mechanically collimated systems; medical diagnostic imaging; medical instrumentation; nuclear medicine; spatial resolution; Cameras; Electrons; Energy measurement; Energy resolution; Gamma ray detection; Gamma ray detectors; Gamma ray effects; Gamma rays; Germanium; Measurement uncertainty;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium, 1997. IEEE
Conference_Location :
Albuquerque, NM
ISSN :
1082-3654
Print_ISBN :
0-7803-4258-5
Type :
conf
DOI :
10.1109/NSSMIC.1997.670574
Filename :
670574