DocumentCode
2816662
Title
Calculation of fast neutron dose in plastic-coated optical fibres
Author
Siebert, B.R.L. ; Henschel, H.
Author_Institution
Phys. Tech. Bundesanstalt, Braunschweig, Germany
fYear
1997
fDate
15-19 Sep 1997
Firstpage
466
Lastpage
471
Abstract
The dose of fast neutrons in optical fibres with hydrogen-containing coating materials is considerably increased by energetic recoil protons. Their contribution to the dose in a SiO2 fibre core is calculated by the Monte Carlo method for different fibre geometries and a fibre optic cable. With 14 MeV neutrons the dose in a single fibre is increased by about 21%, whereas in fibre bundles the dose increase can reach about 170%. Maximum dose enhancement in fibre bundles (about 610%) occurs at neutron energies around 5.5 MeV. The dose increase caused by 14 MeV neutrons in the fibre of a typical laboratory cable is about 124%
Keywords
Monte Carlo methods; neutron effects; optical cables; optical fibres; 14 MeV; Monte Carlo simulation; SiO2; fast neutron dose; fibre bundle; fibre optic cable; optical fibre; plastic coating; proton recoil; single fibre; Coatings; Fiber optics; Gamma ray effects; Gamma rays; Neutrons; Optical fiber cables; Optical fiber testing; Optical fibers; Optical materials; Protons;
fLanguage
English
Publisher
ieee
Conference_Titel
Radiation and Its Effects on Components and Systems, 1997. RADECS 97. Fourth European Conference on
Conference_Location
Cannes
Print_ISBN
0-7803-4071-X
Type
conf
DOI
10.1109/RADECS.1997.698974
Filename
698974
Link To Document