• DocumentCode
    2817457
  • Title

    Medição digital aplicada a estabilizadores e condicionadores CA

  • Author

    De Almeida, Bruno Ricardo ; Batista, Flábio Alberto Bardemaker ; Petry, Clóvis Antônio

  • Author_Institution
    Inst. Fed. de Santa Catarina, Florianopolis, Brazil
  • fYear
    2010
  • fDate
    8-10 Nov. 2010
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    This paper deals with the digital measurement of the true RMS value for use in controlling of AC voltage regulators and in controlling of line conditioners. The algorithms used to calculate the RMS value are presented, as well as the factors that influence the determination of this value. Some aspects are analyzed, as the definition of the true RMS value, the determination of the sampling rate of the signals and the effect of voltage harmonics. Experimental results show the functionality of the hardware implemented where the programs developed are tested to verify the accuracy and calculation time of measurements.
  • Keywords
    voltage control; voltage measurement; voltage regulators; AC voltage regulators; digital measurement; Assembly; Detectors; Digital signal processing; Hardware; Pulse width modulation; Root mean square; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industry Applications (INDUSCON), 2010 9th IEEE/IAS International Conference on
  • Conference_Location
    Sao Paulo
  • Print_ISBN
    978-1-4244-8008-1
  • Electronic_ISBN
    978-1-4244-8009-8
  • Type

    conf

  • DOI
    10.1109/INDUSCON.2010.5739994
  • Filename
    5739994