DocumentCode
2817831
Title
Radiation Testing a Very Low-Noise RHBD ASIC Electrometer
Author
Jones, Andrew R. ; O´Connor, Darren ; Thiemann, Edward ; Drake, Virginia A. ; Newcomb, Gregory ; White, Neil ; Aalami, Dean D. ; Clark, Henry L. ; Ladbury, Raymond L. ; Von Przewoski, Barbara ; Dooley, Sharon ; Finkelstein, Seth ; Haskins, Porter ; Hsu, V
Author_Institution
Lab. for Atmos. & Space Phys., Univ. of Colorado at Boulder, Boulder, CO, USA
fYear
2010
fDate
20-23 July 2010
Firstpage
6
Lastpage
6
Abstract
We report the results of Single Event Effect (SEE) and Total Integrated Dose (TID) testing of a very-low-noise six-channel electrometer Application Specific Integrated Circuit (ASIC) constructed through the MOSIS service using the ON Semiconductor C5N process. The ASICs were designed using Radiation Hard By Design (RHBD) layout rules, and TID mitigation strategies. This testing provides a verification that the device does not show latch-up behavior, and that performance is not unduly compromised by TID. The SEE testing, using heavy ions, took place at the Single Event Effects Facility at Texas A&M University using the 24.8~MeV/u beam with ions Ar, Kr, and Xe giving a range of Linear Energy Transfer (LET) at the device of 7.5-63.5 MeV cm2/mg. No latch-ups were seen even at an elevated temperature (30C). TID testing using protons was conducted at the Indiana University Cyclotron Facility on the Radiation Effects Research Program RERS2 beamline. Parts were tested to a total dose of 300 krad(Si). As these ASICs are constructed using CMOS technology there will be no Enhanced Low Dose Rate Sensitivity (ELDRS).
Keywords
CMOS integrated circuits; application specific integrated circuits; argon; electrometers; integrated circuit testing; ion beam effects; krypton; radiation hardening (electronics); xenon; Ar; CMOS technology; Kr; MOSIS service; TID mitigation strategy; Xe; application specific integrated circuit; enhanced low dose rate sensitivity; latch up behavior; linear energy transfer; radiation hard by design layout; radiation testing; single event effect; temperature 30 C; total integrated dose testing; very low-noise RHBD ASIC electrometer; Application specific integrated circuits; Calibration; Clocks; Radiation effects; Shift registers; Temperature measurement; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Radiation Effects Data Workshop (REDW), 2010 IEEE
Conference_Location
Denver, CO
ISSN
2154-0519
Print_ISBN
978-1-4244-8405-8
Type
conf
DOI
10.1109/REDW.2010.5619512
Filename
5619512
Link To Document