DocumentCode :
2823731
Title :
Alternative configurations of PV module for minimizing the fault effect
Author :
Ghali, Fadia M A ; Syam, Fathy A. ; Abdelaziz, Mohamad M.
Author_Institution :
Electron. Res. Inst., Cairo, Egypt
Volume :
3
fYear :
2003
fDate :
27-30 Dec. 2003
Firstpage :
1085
Abstract :
This paper has proposed two assembling configurations of cells inside a module. These developed techniques have been intensively discussed to synthesize the effect of cells configuration on module losses. The study has reached the conclusion that, the more the degree of parallelism, the less the effect of fault condition on module output maximum power. An alternative configuration realizing the same advantage of reduced losses is achieved by series-parallel configuration.
Keywords :
losses; photovoltaic cells; solar cells; PV cells; PV losses; PV module; alternative configurations; cells configuration; common current mode; common voltage mode; fault effect; module losses; reduced losses; series-parallel configuration; Assembly; Breakdown voltage; Circuit faults; Contact resistance; Manufacturing processes; P-n junctions; Photovoltaic cells; Photovoltaic systems; Semiconductor diodes; Solar power generation; Common current mode; Common voltage mode; PV cells; PV losses;