  • Abstract
    An interface system for measuring rockwool water-content and water conductivity is presented. It is intended for measuring impedances that can be modeled as a parallel combination of a capacitance Cp and a resistance Rp. In the particular application, the capacitance varies from 1 pF to 100 pF and the resistance can be in the range from few tens of ohms up to 5 kΩ The measurements are conducted with a sinusoidal signal having a frequency of 20 MHz. At this frequency the full-scale error for Cp doesn´t exceed 3,5% for a 100 pF range. The full-scale error for the measured Rp remains below 3,7% for a full-scale value of 5 kΩ with the presented measurement principle resolution better than 0,2% can be achieved for both measured components.
  • Keywords
    RC circuits; electric impedance measurement; electrical conductivity; signal resolution; 1 to 100 pF; 20 MHz; 5 kohm; RC circuits; electric impedance measurement system; full scale error; interface system; rockwool substrates; signal resolution; sinusoidal signal; water conductivity; Capacitance measurement; Dielectric constant; Dielectric materials; Dielectric measurements; Electric variables measurement; Electrical resistance measurement; Frequency measurement; Impedance measurement; Permittivity measurement; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Sensors for Industry Conference, 2004. Proceedings the ISA/IEEE
  • Print_ISBN
    0-7803-8143-2
  • Type

    conf

  • DOI
    10.1109/SFICON.2004.1287127
  • Filename
    1287127