• DocumentCode
    2827343
  • Title

    Detection of motion in SPECT using multi-head data combination

  • Author

    Pellot-Barakat, C. ; Ivanovic, M. ; Weber, D.A. ; Shelton, D.K. ; Herment, A.

  • Author_Institution
    California Univ., Davis, CA, USA
  • Volume
    2
  • fYear
    1997
  • fDate
    9-15 Nov 1997
  • Firstpage
    1669
  • Abstract
    An algorithm to automatically detect and eliminate motion in projection data from triple head SPECT systems is proposed. The approach relies on a specific protocol in which each camera rotates 3 times faster than in conventional acquisitions and performs a full 360-degree orbit, instead of the usual partial 120 degrees orbit. This permits to obtain three full sets of data. The hypothesis is that by adequately combining the sets, it is possible in most eases to reconstitute a motion-free set of projection data. The motion detection consists of searching consistent frames through the study by cross-correlating the projection sets as a function of the angle. Plateaus of high correlation are estimated and matched in order to identify projections corresponding to the same position of the subject throughout the study. Different motion situations were created by manually moving a cardiac phantom at different times. In all cases, it was possible to reconstitute the evolution of the motion during the study. When no motion occurred during an interval equal to at least one third of the total acquisition time, high correlation plateaus could be identified. It was then possible to build an optimal complete set of consistent frames from the longest matching plateaus regardless of the frequency and magnitude of motion. Otherwise, an averaging of the three sets was performed, which still improved the quality of the reconstructed slices compared to conventional imaging protocol
  • Keywords
    biomechanics; cardiology; image reconstruction; medical image processing; motion estimation; single photon emission computed tomography; SPECT motion detection; cardiac phantom; conventional imaging protocol; image artifacts; medical diagnostic imaging; motion evolution reconstitution; motion-free projection data set; multihead data combination; nuclear medicine; patient motion; reconstructed slices quality; triple head SPECT systems; Cameras; Detectors; Fractionation; Frequency; Head; Image reconstruction; Imaging phantoms; Motion detection; Protocols; Reconstruction algorithms;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium, 1997. IEEE
  • Conference_Location
    Albuquerque, NM
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-4258-5
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1997.670638
  • Filename
    670638