DocumentCode :
2831316
Title :
Fault Diagnosis of Electric Actuator in the Thermal Power Plant Based on Data-Driven
Author :
Ying-min, Wang ; Feng-bin, Yang
Author_Institution :
Hebei Univ. of Eng., Handan, China
Volume :
1
fYear :
2009
fDate :
16-18 Oct. 2009
Firstpage :
667
Lastpage :
670
Abstract :
Because the past fault diagnostic methods of electric actuator are mostly taken in the control system, and tend to cover up the implementation of the fault itself, and the constant gain fault of actuator is not easy to determine. In response to these shortcomings. The mechanism of the actuator is analyzed in this paper, in order to identify the effective measuring points electric of actuator. A approach based on data-driven to the implementation of the provision of the signal itself to deal with failures is processed and to establish the fault diagnosis system. The method is not only need to establish a complex mathematical model but also with the advantage that need a simple calculation to determine the fault quickly.
Keywords :
electric actuators; fault diagnosis; thermal power stations; complex mathematical model; data-driven; electric actuator; fault diagnosis; signal provision; thermal power plant; Actuators; Control systems; Equations; Failure analysis; Fault diagnosis; Mathematical model; Power generation; Power generation economics; Power system economics; Signal processing; data-driven; discriminate analysis; electric actuator; fault diagnosis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Energy and Environment Technology, 2009. ICEET '09. International Conference on
Conference_Location :
Guilin, Guangxi
Print_ISBN :
978-0-7695-3819-8
Type :
conf
DOI :
10.1109/ICEET.2009.168
Filename :
5364143
Link To Document :
بازگشت