DocumentCode
2831316
Title
Fault Diagnosis of Electric Actuator in the Thermal Power Plant Based on Data-Driven
Author
Ying-min, Wang ; Feng-bin, Yang
Author_Institution
Hebei Univ. of Eng., Handan, China
Volume
1
fYear
2009
fDate
16-18 Oct. 2009
Firstpage
667
Lastpage
670
Abstract
Because the past fault diagnostic methods of electric actuator are mostly taken in the control system, and tend to cover up the implementation of the fault itself, and the constant gain fault of actuator is not easy to determine. In response to these shortcomings. The mechanism of the actuator is analyzed in this paper, in order to identify the effective measuring points electric of actuator. A approach based on data-driven to the implementation of the provision of the signal itself to deal with failures is processed and to establish the fault diagnosis system. The method is not only need to establish a complex mathematical model but also with the advantage that need a simple calculation to determine the fault quickly.
Keywords
electric actuators; fault diagnosis; thermal power stations; complex mathematical model; data-driven; electric actuator; fault diagnosis; signal provision; thermal power plant; Actuators; Control systems; Equations; Failure analysis; Fault diagnosis; Mathematical model; Power generation; Power generation economics; Power system economics; Signal processing; data-driven; discriminate analysis; electric actuator; fault diagnosis;
fLanguage
English
Publisher
ieee
Conference_Titel
Energy and Environment Technology, 2009. ICEET '09. International Conference on
Conference_Location
Guilin, Guangxi
Print_ISBN
978-0-7695-3819-8
Type
conf
DOI
10.1109/ICEET.2009.168
Filename
5364143
Link To Document