Title :
A readout ASIC for GEM detectors
Author :
Deng, Zhi ; Deng, Xiao ; Li, Yancun ; Liu, Yinong ; Li, Yulan
Author_Institution :
Tsinghua Univ., Beijing
fDate :
Oct. 26 2007-Nov. 3 2007
Abstract :
A readout ASIC for GEM (gas electron multiplier) detectors is present. It consists of a low-noise charge preamplifier, a CR-(RC)4 semi-Gaussian shaper and a class-AB buffer for each channel. Fabricated in 0.35 mum CMOS process, it takes about 150 mum x 1500 mum die area and dissipates less than 10 mW per channel. The detailed design and preliminary test results are reported.
Keywords :
CMOS integrated circuits; application specific integrated circuits; nuclear electronics; position sensitive particle detectors; preamplifiers; readout electronics; CMOS process; CR-(RC)4 semiGaussian shaper; GEM detectors; Gas Electron Multiplier; class-AB buffer; low-noise charge preamplifier; readout ASIC; Anodes; Application specific integrated circuits; CMOS process; Detectors; Electrons; Engine cylinders; Particle tracking; Preamplifiers; Prototypes; Signal resolution;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location :
Honolulu, HI
Print_ISBN :
978-1-4244-0922-8
Electronic_ISBN :
1095-7863
DOI :
10.1109/NSSMIC.2007.4436334