DocumentCode :
2835498
Title :
Second generation high-pressure xenon gamma-ray detector
Author :
Beyerle, Albert G. ; Cabrera-Palmer, Belkis ; Little, A. Charlie
Author_Institution :
Mirmar Sensor, Goleta
Volume :
1
fYear :
2007
fDate :
Oct. 26 2007-Nov. 3 2007
Firstpage :
613
Lastpage :
615
Abstract :
An innovative design of high-pressure xenon (HPXe) gamma-ray detector without Frish grid provides a marked improvement in vibration insensitivity and manufacturability over that demonstrated the gridded designs. This paper focuses on the architecture and performance of a Mirmar Sensor 1.5" gridless HPXe detector. This discussion includes descriptions of the hardware and software features necessary to implement a gridless detector design. Performance data is presented that demonstrates 2% resolution for 137Cs and a seven-fold improvement in microphonic rejection over previous designs.
Keywords :
gamma-ray apparatus; gas scintillation detectors; Mirmar Sensor gridless HPXe detector; gridless detector design; high-pressure xenon gamma-ray detector; microphonic rejection; Anodes; Cathodes; Electrons; Energy resolution; Gamma ray detection; Gamma ray detectors; Manufacturing; Power supplies; Voltage; Xenon;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location :
Honolulu, HI
ISSN :
1095-7863
Print_ISBN :
978-1-4244-0922-8
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2007.4436407
Filename :
4436407
Link To Document :
بازگشت