Title :
Aligning the CMS muon endcap detector with a system of optical sensors
Author :
Hohlmann, Marcus ; Baksay, Gyöngyi ; Guragain, Samir ; Andreev, Valery ; Yang, Xiaofeng ; Bellinger, James ; Carlsmith, Duncan ; Feyzi, Garshid ; Loveless, Richard J. ; Northacker, David ; Eartly, David P. ; Prokofiev, Oleg ; Sknar, Vladimir
Author_Institution :
Florida Inst. of Technol., Melbourne
fDate :
Oct. 26 2007-Nov. 3 2007
Abstract :
The positions and orientations of one sixth of 468 large cathode strip chambers in the endcaps of the CMS muon detector are directly monitored by several hundred sensors including 2-D optical sensors with linear CCDs illuminated by cross-hair lasers. Position measurements obtained by photo- grammetry and survey under field-off conditions show that chambers in the +Z endcap have been placed on the yoke disks with an average accuracy of about plusmn1 mm in all 3 dimensions. We reconstruct absolute Zciws-positions and orientations of chambers at B=0T and B=4T using data from the optical alignment system. The measured position resolution and sensitivity to relative motion is ~60 mum. The precision for measuring chamber positions taking into account mechanical tolerances is ~270 mum. Comparing reconstruction of optical alignment data and photogrammetry measurements at B=0T indicates an accuracy of ~ 680 mum currently achieved with the hardware alignment system. Optical position measurements at B=4T show significant chamber displacements of up to 13 mm due to yoke disk deformation.
Keywords :
CCD image sensors; measurement by laser beam; muon detection; photogrammetry; position sensitive particle detectors; CMS muon endcap detector; cathode strip chambers; chamber orientations; cross-hair lasers; hardware alignment system; linear CCDs; magnetic flux density 0 T; magnetic flux density 4 T; mechanical tolerances; optical alignment system; optical sensors; photogrammetry; position resolution; yoke disk deformation; Cathodes; Collision mitigation; Current measurement; Hardware; Mechanical variables measurement; Mesons; Motion measurement; Optical sensors; Position measurement; Strips;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location :
Honolulu, HI
Print_ISBN :
978-1-4244-0922-8
Electronic_ISBN :
1095-7863
DOI :
10.1109/NSSMIC.2007.4436418