Title :
Measurement of the mass attenuation coefficients of Ge and BGO for high-energy gamma-rays
Author :
Harada, Hideo ; Kitatani, Fumito ; Hara, Kaoru Y. ; Toyokawa, Hiroyuki ; Kaihori, Takeshi ; Utsunomiya, Hiroaki
Author_Institution :
Japan Atomic Energy Agency, Tokai
fDate :
Oct. 26 2007-Nov. 3 2007
Abstract :
The gamma-ray mass attenuation coefficients of important materials for gamma-ray detection have been measured using the laser-Compton backscattering gamma-rays (LCS gamma-rays) and the high-resolution high-energy photon spectrometer (HHS). The preliminary results performed for materials (Ge and BGO) are presented for gamma-ray energy of 5.1 MeV. The measured data are compared with tabulated theoretical calculations.
Keywords :
gamma-ray detection; germanium radiation detectors; scintillation counters; BGO detector; Ge detector; LCS; electron volt energy 5.1 MeV; gamma-ray detection; high-energy gamma-rays; high-resolution high-energy photon spectrometer; laser-Compton backscattering; mass attenuation coefficients; Attenuation measurement; Backscatter; Detectors; Laser theory; Nuclear and plasma sciences; Nuclear measurements; Optical attenuators; Optical materials; Ring lasers; Spectroscopy;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location :
Honolulu, HI
Print_ISBN :
978-1-4244-0922-8
Electronic_ISBN :
1095-7863
DOI :
10.1109/NSSMIC.2007.4436421