DocumentCode :
2841027
Title :
Breathing Resistance in Scuba Regulators
Author :
Riegel, P.S.
Author_Institution :
Battelle-Columbus Laboratories, Columbus, OH, USA
fYear :
1976
fDate :
13-15 Sept. 1976
Firstpage :
556
Lastpage :
561
Abstract :
The single-hose two-stage demand regulator is the most common means of supplying divers with gas. As diving conditions become more severe, this regulator sometimes exhibits excessive breathing resistance. This paper discusses breathing resistance and its sources, including: (1) Respiration and breathing resistance (2) Description of regulation system (3) Regulator operation (4) Sources of breathing resistance (a) Hydrostatic differential (b) Valve friction (c) Setup bias (d) Valve spring compression (e) Valve unbalance (f) Pressure drop across mouthpiece (g) Pressure drop across exhaust valve (5) Recommendations for improved operation.
Keywords :
Electrical resistance measurement; Friction; Immune system; Laboratories; Lungs; Mouth; Regulators; Sea measurements; Springs; Valves;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
OCEANS '76
Conference_Location :
Washington, DC, USA
Type :
conf
DOI :
10.1109/OCEANS.1976.1154292
Filename :
1154292
Link To Document :
بازگشت