    Quantitative imaging with low-dose CT in the PET/CT system

  • Author

    Nam, Sora ; Kim, Hee-Joung ; Jung, Ji Young ; Cho, Hyo-Min ; Le, Chang-Lae

  • Author_Institution
    Yonsei Univ., Wonjusi
  • Volume
    5
  • fYear
    2007
  • fDate
    Oct. 26 2007-Nov. 3 2007
  • Firstpage
    3436
  • Lastpage
    3439
  • Abstract
    The use of PET/CT systems in clinical applications has rapidly increased of late. Not only has their diagnostic value increased due to their superior statistical noise characteristics; they have also shortened the acquisition time for attenuation correction compared to a single-modality PET system. Most commercially available PET/CT systems use the CT scan for attenuation correction instead of the transmission scan, which uses a radioactive source, such as 137Cs or 68Ge. The effective dose of CT attenuation correction, however, is up to 118 times larger than that of radioactive isotope attenuation correction. As such, an increased dose is expected during the CT scan. The purpose of this study is to evaluate the quality of PET images that have been reconstructed using a CT attenuation map in various CT tube currents. Image data were obtained, using a 3D Hoffman brain phantom and a cylindrical phantom, for both the GE DSTe PET/CT and Philips GEMINI PET/CT systems. The acquisition protocols of the DSTe and GEMINI systems for PET studies were based on the parameters used by Turkington et al. and Gregory et al., respectively, in the studies they conducted. The CT data that were used to create an attenuation map were acquired from various tube currents, from a diagnostic dose to an ultra-low dose. The CT image quality was evaluated by measuring the standard deviation (SD) of the cylindrical phantom filled with water. The PET image quality was evaluated by computing the activity ratio of the gray and white matter in the 3D Hoffman brain phantom images. In addition, the coefficient of variance (COV) was calculated to evaluate the CT and PET images. The SDs of the CT data and the COVs of the CT images decreased when the tube currents increased. The activity ratios of the gray and white matter with a ventricle area in the PET images remained almost constant for the CT attenuation maps that used various tube currents. The DSTe and GEMINI systems´ activity ratios were approxim- ately 3.76plusmn0.03 and 3.86plusmn0.03. The COVs of the PET images were almost the same in spite of the fact that the PET images´ attenuations were corrected with the use of different CT data. The results indicated that the quality of the PET images whose attenuations were corrected using a low-dose CT was comparable to that of the PET images whose attenuations were corrected using a diagnostic-dose CT. In conclusion, if the CT exam does not require a high-quality diagnostic CT, the use of the low-dose CT rather than the diagnostic-dose CT is recommended.
  • Keywords
    biochemistry; brain; computerised tomography; dosimetry; image reconstruction; neurophysiology; phantoms; positron emission tomography; 3D Hoffman brain phantom; CT attenuation correction; CT tube currents; GE DSTe systems; PET image quality; PET-CT systems; Philips GEMINI systems; coefficient of variance; cylindrical phantom; gray matter; low-dose CT; standard deviation measurement; white matter; Attenuation; Computed tomography; Image quality; Image reconstruction; Imaging phantoms; Isotopes; Measurement standards; Neoplasms; Positron emission tomography; Whole-body PET;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
  • Conference_Location
    Honolulu, HI
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-0922-8
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2007.4436868
  • Filename
    4436868