• DocumentCode
    2843724
  • Title

    Closed circuit hot water diver heating systems

  • Author

    English, J.G.

  • Author_Institution
    Can-Dive Oceaneering, North Vancouver, British Columbia, Canada
  • fYear
    1977
  • fDate
    17-19 Oct. 1977
  • Firstpage
    198
  • Lastpage
    201
  • Abstract
    Can-Dive Services Ltd., the Canadian subsidiary of Oceaneering International, Inc., working in conjunction with Vickers Oceanics of Edinburgh, Scotland, has developed and successfully applied a closed circuit diver heating system for submersible lockout operations in the North Sea. Following bench and hyperbaric tests to 1,000 FSW, the unit has been installed on the Vickers L-1 submersible. The initial working dive was a 3 hour, 33 minute lockout at 475 feet, 5\\deg C on the Oxydental Piper A platform. The use of equipment of this type represents a significant breakthrough in providing divers with a safe, reliable heating system when working in situations where there is limited power available. This paper provides a brief outline of some of the problems inherent with closed circuit systems and comments on methods of improving the efficiency of the unit. A list of requirements for an improved distribution garment is also provided.
  • Keywords
    Batteries; Clothing; Costs; Energy loss; Fabrication; Glass; Ocean temperature; Resistance heating; Underwater vehicles; Water heating;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    OCEANS '77 Conference Record
  • Conference_Location
    Los Angeles, CA, USA
  • Type

    conf

  • DOI
    10.1109/OCEANS.1977.1154456
  • Filename
    1154456