DocumentCode :
2843892
Title :
A prototype CZT-based PET scanner for high resolution mouse brain imaging
Author :
Vaska, P. ; Dragone, A. ; Lee, W. ; Kim, D.-H. ; Pratte, J.-F. ; Cui, Y.-G. ; Fried, J. ; Krishnamoorthy, S. ; Bolotnikov, A. ; Park, S.-J. ; Connor, P.O. ; Dilmanian, F.A. ; James, R.B.
Author_Institution :
Brookhaven Nat. Lab., Upton
Volume :
5
fYear :
2007
fDate :
Oct. 26 2007-Nov. 3 2007
Firstpage :
3816
Lastpage :
3819
Abstract :
One of the most challenging and potentially rewarding research applications of PET is imaging of the mouse brain. Although very high spatial resolution is required (< ~1 mm), there is a much wider variety of transgenic models in mouse compared to the rat. The solid state material CdZnTe (CZT) has long held promise for high resolution PET. Compared to scintillators, its limitations in time resolution and sensitivity can in some ways be compensated by its extremely high spatial and energy resolution, its compact geometry, and by sophisticated data processing techniques. Using such techniques, a time resolution of ~10 ns has been demonstrated for ~1 cm thick CZT pixel detectors, and this may be sufficient for mouse studies. The depth-of-interaction capability and high energy resolution can improve sensitivity by allowing detectors to be placed very close to the subject and by enabling both reconstruction of detector-scattered events and rejection of object-scattered events. A full-ring prototype scanner has been designed to demonstrate feasibility of the concept, consisting of 6 CZT pixel detectors in a novel geometry. The design of the detector, front-end electronics components, and data acquisition are presented, along with performance characterization of the custom-manufactured CZT detectors.
Keywords :
II-VI semiconductors; brain; cadmium compounds; data acquisition; image reconstruction; image resolution; medical image processing; positron emission tomography; semiconductor counters; zinc compounds; CZT-based PET scanner; CdZnTe; data acquisition; data processing; depth-of-interaction capability; detector sensitivity; detector-scattered event reconstruction; energy resolution; front-end electronics components; high resolution mouse brain imaging; object-scattered event ejection; spatial resolution; time resolution; Brain; Detectors; Energy resolution; Geometry; High-resolution imaging; Image resolution; Mice; Positron emission tomography; Prototypes; Spatial resolution;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location :
Honolulu, HI
ISSN :
1095-7863
Print_ISBN :
978-1-4244-0922-8
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2007.4436952
Filename :
4436952
Link To Document :
بازگشت