DocumentCode
2845005
Title
ITER environmental source term assessment for some reference accident sequences
Author
Cambi, G. ; Pace, LDi ; Cepraga, D.G. ; Porfiri, M.T.
Author_Institution
Dipt. di Fisica, Bologna Univ., Italy
Volume
1
fYear
1997
fDate
6-10 Oct 1997
Firstpage
179
Abstract
The paper presents the environmental source term EST evaluation for two ITER reference accident sequence related to the divertor primary heat transfer system. An ex-vessel LOCA and a pump seizure have been considered as initiating events. The thermal-hydraulic transient analysis and the containment response to the accident have been assessed using the Athena and Intra codes while the Naua Mod 5M code has been considered for aerosol transport to the environment. Ground and stack releases are evaluated, both for tritium and activated materials
Keywords
accidents; aerosols; fusion reactor safety; nuclear engineering computing; pumps; Athena code; ITER; Intra code; LOCA; Naua Mod 5M code; T; activated materials; aerosol transport; containment response; divertor primary heat transfer system; environmental source term assessment; ex-vessel LOCA; ground release; pump seizure; reference accident sequences; stack release; thermal-hydraulic transient analysis; tritium; Accidents; Aerosols; Coolants; Cooling; Heat pumps; Heat transfer; Inductors; Performance analysis; Safety; Steady-state;
fLanguage
English
Publisher
ieee
Conference_Titel
Fusion Engineering, 1997. 17th IEEE/NPSS Symposium
Conference_Location
San Diego, CA
Print_ISBN
0-7803-4226-7
Type
conf
DOI
10.1109/FUSION.1997.687015
Filename
687015
Link To Document