DocumentCode :
2845216
Title :
Starting Transient Characteristics of Metal Halide Lamps
Author :
Tang, Sheng Y. ; Chen, Jia H. ; Lee, Ching R. ; Cheng, Hung L.
Author_Institution :
Nat. Sun Yat-Sen Univ., Kaohsiung
fYear :
2007
fDate :
2-5 April 2007
Firstpage :
711
Lastpage :
716
Abstract :
This paper aims at investigating the effects of the lamp current and power on the electrical behavior, the spectral distribution and the produced luminance. Based on the results observed, the starting transient characteristics can be well understood and the times for entering thermal equilibrium and the steady-state light output can be defined in a more reasonable manner. Experimental evidence shows that the glow-to-arc transition stage takes most of the transient period, and the starting time of a metal halide lamp can be effectively shortened by increasing the lamp current during the glow-to-arc transition stage. More importantly, a specifically-regulated operating power enables the lamp to further enhance luminance, and hence to reduce the starting transient period remarkably.
Keywords :
brightness; lamp accessories; metal vapour lamps; electrical behavior; electronic ballast; glow-to-arc transition stage; lamp current; lamp power; luminance; metal halide lamps; spectral distribution; starting transient characteristics; steady-state light output; thermal equilibrium; Buck converters; Circuit testing; Electric breakdown; Electronic ballasts; Electronic equipment testing; High intensity discharge lamps; Inverters; Resonance; Steady-state; Voltage; Metal halide lamp; electronic ballast; starting transient;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Conversion Conference - Nagoya, 2007. PCC '07
Conference_Location :
Nagoya
Print_ISBN :
1-4244-0844-X
Electronic_ISBN :
1-4244-0844-X
Type :
conf
DOI :
10.1109/PCCON.2007.373044
Filename :
4239234
Link To Document :
بازگشت