Title :
Evaluation of a MR-compatible CZT detector
Author :
Després, Philippe ; Izaguirre, Enrique W. ; Liu, Siyuan ; Cirignano, Leonard J. ; Kim, Hadong ; Wendland, Michael F. ; Shah, Kanai S. ; Hasegawa, Bruce H.
Author_Institution :
Centre Hospitalier de l´´Univ. de Montreal, Montreal
fDate :
Oct. 26 2007-Nov. 3 2007
Abstract :
Multimodality imaging is increasingly relevant in many clinical and preclinical fields. PET/CT and SPECT/CT studies, for instance, generally provide more information than the same imaging modalities taken separately. This synergistic effect, obtained by combining anatomical and functional information, also would be desirable for magnetic resonance imaging (MRI), a nonionizing modality that provides excellent spatial resolution and soft-tissue contrast. The development of a PET/MRI or SPECT/MRI system however represents a significant technological challenge, in part due to the effect of the strong MRI magnetic field on the PET/SPECT detection subsystem. This environment complicates the use of photomultiplier tubes (PMTs) and rather favors solid-state detection technologies. As a proof of principle, we have studied the behavior of a MR-compatible CdZnTe (CZT) detector, a room-temperature semiconductor already used in some SPECT systems. The detector, made from a single 5x5x2 mm3 CZT crystal, was coupled to a Cremat CR-110 preamplifier with nonmagnetic connectors. The whole detector/preamplifier assembly was tested within a static magnetic field while the radiation detector electronics remained outside the magnet room. We measured the energy resolution of the detector from 57Co spectra both inside and outside the magnet. The results suggest that the static magnetic field does not affect the energy resolution of the CZT detector, making it a good candidate for the development of a MRI device combining a nuclear medicine imaging subsystem.
Keywords :
II-VI semiconductors; biomedical MRI; cadmium compounds; position sensitive particle detectors; positron emission tomography; semiconductor counters; single photon emission computed tomography; wide band gap semiconductors; zinc compounds; CdZnTe; Cremat CR-110 preamplifier; MR-compatible CZT detector; PET system; SPECT system; energy resolution; magnetic resonance imaging; multimodality medical imaging systems; nonmagnetic connectors; nuclear medicine imaging subsystem; radiation detector electronics; room-temperature semiconductor; static magnetic field; Computed tomography; Electronic equipment testing; Energy resolution; Magnetic field measurement; Magnetic resonance imaging; Magnetic separation; Positron emission tomography; Preamplifiers; Radiation detectors; Spatial resolution;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location :
Honolulu, HI
Print_ISBN :
978-1-4244-0922-8
Electronic_ISBN :
1095-7863
DOI :
10.1109/NSSMIC.2007.4437072