Fully 4D reconstruction applied to respiratory gated PET acquisitions
Author :
Grotus, Nicolas ; Reader, Andrew J. ; Brinks, Ralph ; Maniawski, Piotr ; Servois, Vincent ; Rosenwald, Jean-Claude ; Giraud, Philippe ; Buvat, Irène
Volume :
6
fYear :
2007
fDate :
Oct. 26 2007-Nov. 3 2007
Firstpage :
4401
Lastpage :
4405
Abstract :
Respiratory gating is a helpful technique to reduce motion blur in PET images of the lungs. Efforts still need to be made on reconstruction schemes adapted to this kind of data, since gated data are usually of low statistical quality. A 4D joint- estimation image reconstruction method is tested and compared to classic OSEM algorithms on list-mode data acquired with a Philips Gemini GXL PET-CT scanner, using the NEMA IEC body phantom. The Varian RPM system was used to synchronize the 20-minute PET acquisition with the respiration signal. The list-mode events were sorted into eight gates. Four reconstruction schemes were compared: 4D, independent-frame OSEM, independent-frame OSEM followed by temporal filtering between the 8 gates and non-gated acquisitions reconstructed with OSEM. Results were evaluated in terms of signal-to-noise ratio (SNR) and contrast as a function of iteration number for every reconstruction algorithm. The SNR was evaluated from ten different 2-minute intervals of the original list-mode data. Contrast was calculated as the ratio of the background activity to the activity in the cold cylinder inside the phantom. The influence of the number of basis functions used in the 4D reconstruction algorithm was studied. Results show that in the gated images, the SNR is 2.3 times greater when using 4D reconstruction compared to independent reconstruction. 4D reconstruction helps recover the same SNR as non-gated acquisition. Temporal filtering of independent-frame reconstructed images yielded similar contrast - SNR trade-off as 4D reconstruction only in gated frames with little residual movement, but not in the gated frames still including substantial movement. It was also checked that using 4D reconstruction affects only slightly the motion deblurring effect of respiratory gating.
Keywords :
image reconstruction; lung; positron emission tomography; Philips Gemini GXL PET-CT scanner; fully 4D reconstruction; image reconstruction; lungs; positron emission tomography; respiratory gated PET acquisitions; signal-to-noise ratio; Cancer; Filtering; IEC; Image reconstruction; Imaging phantoms; Lesions; Lungs; Positron emission tomography; Reconstruction algorithms; Signal to noise ratio;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location :
Honolulu, HI
ISSN :
1095-7863
Print_ISBN :
978-1-4244-0922-8
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2007.4437088
Filename :
4437088
Link To Document :
بازگشت