• DocumentCode
    2846485
  • Title

    Effects of LSO detector intrisic radioactivity on SPECT imaging

  • Author

    Yao, Rutao ; Ma, Tianyu ; Shao, Yiping

  • Author_Institution
    State Univ. of New York at Buffalo, Buffalo
  • Volume
    6
  • fYear
    2007
  • fDate
    Oct. 26 2007-Nov. 3 2007
  • Firstpage
    4497
  • Lastpage
    4502
  • Abstract
    This work was part of a feasibility study of developing SPECT imaging capability on a lutetium oxyorthosilicate (LSO)-based animal PET system. The SPECT aspect of the system was enabled by inserting a collimator assembly inside the detector ring and acquiring data in singles mode. The LSO detectors were used for both PET and SPECT imaging. The intrinsic radioactivity of 176 Lu in the LSO crystals, however, contaminates the SPECT data more severely than for PET imaging. This work was to study the imaging characteristics of the intrinsic LSO activity, the effects of correction, and the minimal activity level required for usable SPECT imaging. To understand the structural and noise patterns of LSO activity in images, measured high counts projections from LSO activity only and simulated multiple-replicates of low counts projections from LSO activity with and without a uniform phantom in the field-of-view (FOV) were reconstructed. To identify the minimal activity levels needed for obtaining useful tomographic images with the existence of LSO activity, we derived a formula to estimate the minimal activity in the FOV of one detector crystal ring that would yield a net detectable signal in projection data. A series of phantoms with different activity distribution patterns and total activity levels were scanned for variable length of time through simulation and experiments. The LSO contributions to each study were estimated from a long LSO background acquisition dataset and corrected prior to iterative image reconstruction. The LSO activity showed up as concentric rings in a reconstructed tomographic image. The LSO activity estimation and correction method was effective and it reduced the activity level required for producing images with expected visual patterns to about V* of the level needed without the correction. The minimal activity levels predicted by the projection data based formula correlated well with the activity levels needed for obtaining visible image patterns - observed in simulated and experimental studies. Phantom studies demonstrated that while image quality was dependent on source distribution pattern, activity level, and acquisition time, SPECT imaging on LSO based animal PET is feasible with practical dose level and acquisition time used in animal imaging.
  • Keywords
    collimators; data acquisition; image reconstruction; medical image processing; phantoms; single photon emission computed tomography; solid scintillation detectors; LSO detector; SPECT imaging; collimator assembly; data acquisition; detector ring; image quality; imaging characteristics; intrinsic radioactivity; iterative image reconstruction; lutetium oxyorthosilicate; noise patterns; phantom studies; structural patterns; visual patterns; Animals; Assembly systems; Collimators; Crystals; Detectors; Image reconstruction; Imaging phantoms; Noise measurement; Optical imaging; Positron emission tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
  • Conference_Location
    Honolulu, HI
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-0922-8
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2007.4437110
  • Filename
    4437110