DocumentCode :
2846532
Title :
Towards a 30 kW/liter, Three-Phase Unity Power Factor Rectifier
Author :
Round, S.D. ; Karutz, P. ; Heldwein, M.L. ; Kolar, J.W.
Author_Institution :
ETH Zurich, Zurich
fYear :
2007
fDate :
2-5 April 2007
Firstpage :
1251
Lastpage :
1259
Abstract :
In this paper, a forced air-cooled, 400 kHz, 10 kW Vienna rectifier with a power density of 8.5 kW/liter is presented. To further improve the power density, the switching frequency is increased to reduce the EMI filter volume. A design for an 18.5 kW/liter, 2.5 MHz rectifier is proposed. By using today´s technology, it is calculated that the maximum power density for a forced air-cooled and water-cooled rectifier is 20.8 kW/liter and 24 kW/liter respectively. To achieve 30 kW/liter, improvements must be made in passive component material properties, reducing semiconductor losses and improving the cooling system.
Keywords :
electromagnetic interference; power factor; power filters; rectifying circuits; switching convertors; EMI filter; Vienna rectifier; frequency 2.5 MHz; maximum power density; passive component material properties; power density; semiconductor loss reduction; switching frequency; three-phase unity power factor rectifier; water-cooled rectifier; Diodes; Power supplies; Reactive power; Rectifiers; Switches; Switching frequency; Thyristors; Topology; Virtual reality; Voltage; Compact power supply; High power density; Unity power factor; Vienna Rectifier;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Conversion Conference - Nagoya, 2007. PCC '07
Conference_Location :
Nagoya
Print_ISBN :
1-4244-0844-X
Electronic_ISBN :
1-4244-0844-X
Type :
conf
DOI :
10.1109/PCCON.2007.373126
Filename :
4239316
Link To Document :