DocumentCode :
2846947
Title :
Development of neutron gaseous detector with GEM
Author :
Uno, S. ; Sekimoto, M. ; Murakami, T. ; Tanaka, M. ; Nakagawa, S. ; Nakano, E. ; Sugiyama, F. ; Nagaya, K. ; Sugiyama, A. ; Uchida, T.
Author_Institution :
KEK, Tsukuba
Volume :
6
fYear :
2007
fDate :
Oct. 26 2007-Nov. 3 2007
Firstpage :
4623
Lastpage :
4626
Abstract :
We are developing new neutron gaseous detector with Gas Electron Multiplier (GEM) as a detector for material science using thermal (cold) neutron at strong pulsed sources. For detection of neutron, Boron is coated on the both surfaces of one GEM foil. In order to obtain higher efficiency, several GEM foils are stacked in a chamber. A prototype chamber was constructed with 100 mmtimes100 mm GEM foils and a beam test was performed at a research reactor in Japan. Results show the detection efficiency is 30% for 0.22 nm thermal neutron and the position resolution is around 0.5 mm. Uniform 2D position without distortion can be obtained. Diffraction pattern for a single crystal can be clearly observed.
Keywords :
electron multiplier detectors; neutron detection; position sensitive particle detectors; GEM; boron; diffraction pattern; gas electron multiplier; material science; neutron detection; neutron gaseous detector; prototype chamber; thermal neutron; Boron; Detectors; Diffraction; Electron multipliers; Inductors; Materials science and technology; Neutrons; Performance evaluation; Prototypes; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location :
Honolulu, HI
ISSN :
1095-7863
Print_ISBN :
978-1-4244-0922-8
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2007.4437139
Filename :
4437139