• DocumentCode
    2847125
  • Title

    Harmonics induced uncertainty in phase noise measurements

  • Author

    Calbaza, Dorin ; Gupta, Chandra ; Rohde, Ulrich L. ; Poddar, Ajay K.

  • Author_Institution
    Synergy Microwave Corp., 201 McLean Boulevard, Paterson, NJ 07504, USA
  • fYear
    2012
  • fDate
    17-22 June 2012
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    RF signals in VCOs, PLLs and synthesizers are characterized by signal power, harmonic content and phase noise. These parameters have to be accurately measured in order to guarantee the system performance. This paper focuses on the relationship between the signal´s harmonic content and the precision of the phase noise measurement in test equipment. The phase noise measurement´s accuracy is degraded when the measured signal has high harmonics. We demonstrate a case in which a 3rd harmonic level of −7dBc results in a 12dB variation in the phase noise measurement´s accuracy. Based on our studies, the phase noise test setup should include filters between the source and the test equipment to bring down the harmonic level to −20 dBc max.
  • Keywords
    Harmonic analysis; Low pass filters; Mixers; Noise measurement; Phase measurement; Phase noise; Power harmonic filters; Measurement uncertainty; Phase noise;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Symposium Digest (MTT), 2012 IEEE MTT-S International
  • Conference_Location
    Montreal, QC, Canada
  • ISSN
    0149-645X
  • Print_ISBN
    978-1-4673-1085-7
  • Electronic_ISBN
    0149-645X
  • Type

    conf

  • DOI
    10.1109/MWSYM.2012.6258417
  • Filename
    6258417