DocumentCode :
2847271
Title :
Design considerations for high frequency co-axial winding power transformers
Author :
Rauls, Mark S. ; Novotny, Donald W. ; Divan, Deepakraj M.
Author_Institution :
Dept. of Electr. & Comput. Eng., Wisconsin Univ., Madison, WI, USA
fYear :
1991
fDate :
Sept. 28 1991-Oct. 4 1991
Firstpage :
946
Abstract :
An examination is made of the important loss aspects of the design of co-axial winding transformers such as the influence of skin effect on winding resistance, the variation of the core loss caused by nonuniform core flux density, and the choice of the principle dimensions and aspect ratios for maximum efficiency. Experimental measurements on a 50 kVA 50 kHz unit are included to confirm portions of the analytical results and suggested design procedures.<>
Keywords :
losses; power transformers; skin effect; transformer cores; transformer windings; 50 kHz; 50 kVA; co-axial winding power transformers; core loss; high frequency; loss aspects; nonuniform core flux density; skin effect; winding resistance; Conductors; Core loss; DC-DC power converters; Frequency conversion; Inductance; Magnetic cores; Magnetic flux; Power transformers; Resonance; Transformer cores;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industry Applications Society Annual Meeting, 1991., Conference Record of the 1991 IEEE
Conference_Location :
Dearborn, MI, USA
Print_ISBN :
0-7803-0453-5
Type :
conf
DOI :
10.1109/IAS.1991.178351
Filename :
178351
Link To Document :
بازگشت