DocumentCode
2847271
Title
Design considerations for high frequency co-axial winding power transformers
Author
Rauls, Mark S. ; Novotny, Donald W. ; Divan, Deepakraj M.
Author_Institution
Dept. of Electr. & Comput. Eng., Wisconsin Univ., Madison, WI, USA
fYear
1991
fDate
Sept. 28 1991-Oct. 4 1991
Firstpage
946
Abstract
An examination is made of the important loss aspects of the design of co-axial winding transformers such as the influence of skin effect on winding resistance, the variation of the core loss caused by nonuniform core flux density, and the choice of the principle dimensions and aspect ratios for maximum efficiency. Experimental measurements on a 50 kVA 50 kHz unit are included to confirm portions of the analytical results and suggested design procedures.<>
Keywords
losses; power transformers; skin effect; transformer cores; transformer windings; 50 kHz; 50 kVA; co-axial winding power transformers; core loss; high frequency; loss aspects; nonuniform core flux density; skin effect; winding resistance; Conductors; Core loss; DC-DC power converters; Frequency conversion; Inductance; Magnetic cores; Magnetic flux; Power transformers; Resonance; Transformer cores;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Society Annual Meeting, 1991., Conference Record of the 1991 IEEE
Conference_Location
Dearborn, MI, USA
Print_ISBN
0-7803-0453-5
Type
conf
DOI
10.1109/IAS.1991.178351
Filename
178351