Title :
Design considerations for high frequency co-axial winding power transformers
Author :
Rauls, Mark S. ; Novotny, Donald W. ; Divan, Deepakraj M.
Author_Institution :
Dept. of Electr. & Comput. Eng., Wisconsin Univ., Madison, WI, USA
fDate :
Sept. 28 1991-Oct. 4 1991
Abstract :
An examination is made of the important loss aspects of the design of co-axial winding transformers such as the influence of skin effect on winding resistance, the variation of the core loss caused by nonuniform core flux density, and the choice of the principle dimensions and aspect ratios for maximum efficiency. Experimental measurements on a 50 kVA 50 kHz unit are included to confirm portions of the analytical results and suggested design procedures.<>
Keywords :
losses; power transformers; skin effect; transformer cores; transformer windings; 50 kHz; 50 kVA; co-axial winding power transformers; core loss; high frequency; loss aspects; nonuniform core flux density; skin effect; winding resistance; Conductors; Core loss; DC-DC power converters; Frequency conversion; Inductance; Magnetic cores; Magnetic flux; Power transformers; Resonance; Transformer cores;
Conference_Titel :
Industry Applications Society Annual Meeting, 1991., Conference Record of the 1991 IEEE
Conference_Location :
Dearborn, MI, USA
Print_ISBN :
0-7803-0453-5
DOI :
10.1109/IAS.1991.178351