• DocumentCode
    2850881
  • Title

    Study on time -divided double optical paths ultraviolet fluorescence for concentration measuring of sulfur dioxide

  • Author

    Nian, Shanpo ; Hou, Caixia ; Chen, Lei ; Gong, Ruikun ; Zhang, Guangxiang ; Tian, Yansong

  • Author_Institution
    Coll. of Comput. & Autom. Control, Hebei Polytech. Univ., Tangshan, China
  • fYear
    2010
  • fDate
    26-28 May 2010
  • Firstpage
    245
  • Lastpage
    247
  • Abstract
    The research on the detection of sulfur dioxide concentration in flue-gas is a hot topic all the time. Based on the analysis of the measuring principles for the sulfur dioxide concentration using ultraviolet fluorescence method, one new measuring method using time-divided double optical paths is proposed. This method overcomes the problems of cross sensitivity and background noise in single path measurement, because it takes advantage of the fluorescence signals produced by the alternation of two light filters.
  • Keywords
    flue gases; fluorescence; optoelectronic devices; flue-gas; single path measurement; sulfur dioxide concentration measurement; time-divided double optical paths; time-divided double optical paths ultraviolet fluorescence; Biomedical optical imaging; Electromagnetic wave absorption; Equations; Fluorescence; High speed optical techniques; Optical filters; Optical noise; Optical sensors; Pollution measurement; Time measurement; cross sensitivity; fluorescent measurement; sulfur dioxide; time-divided double optical paths;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Control and Decision Conference (CCDC), 2010 Chinese
  • Conference_Location
    Xuzhou
  • Print_ISBN
    978-1-4244-5181-4
  • Electronic_ISBN
    978-1-4244-5182-1
  • Type

    conf

  • DOI
    10.1109/CCDC.2010.5499080
  • Filename
    5499080