DocumentCode :
2851387
Title :
The TerraSAR-X Active Calibration Instruments and Performance Analysis
Author :
Lenz, Rainer ; Wiesbeck, Werner
Author_Institution :
Inst. fur Hochstfrequenztechnik und Elektron., Univ. Karlsruhe, Karlsruhe
fYear :
2006
fDate :
July 31 2006-Aug. 4 2006
Firstpage :
97
Lastpage :
100
Abstract :
This paper describes the development and system concept for an active and highly integrated, digitally controlled SAR system calibrator. For precise and high-quality SAR data, precise ground targets are necessary for external calibration of the SAR data. Compared to passive targets, active radar targets like transponders offer more features. The recording of the transmitted radar signals from the satellite becomes possible and allows additional data analysis and data correction. A total of 18 active transponder and receiver systems and 16 receiver only systems will be fabricated for the TerraSAR-X calibration campaign in fall 2006.
Keywords :
calibration; data analysis; geophysical equipment; remote sensing by radar; synthetic aperture radar; transponders; AD 2006; TerraSAR-X active calibration instruments; active transponder; data analysis; data correction; ground targets; passive targets; radar signals recording; receiver systems; Calibration; Control systems; Data analysis; Digital control; Instruments; Passive radar; Performance analysis; Satellites; Spaceborne radar; Transponders;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Geoscience and Remote Sensing Symposium, 2006. IGARSS 2006. IEEE International Conference on
Conference_Location :
Denver, CO
Print_ISBN :
0-7803-9510-7
Type :
conf
DOI :
10.1109/IGARSS.2006.30
Filename :
4241177